1 to 10KVA
AC input voltage: 110Vac/ 230Vac, 50/60hz
Battery voltage: 48Vdc
AC output voltage: 110Vac/ 230Vac, 50/60hz
With built-in big charger (>20A)
LCD display (optional)
1 to 6K: Rack mount and tower convertiable
7.5k to 10K: Tower mount
Safety agency approved
Ensure the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. CE approvel and FCC class B
Serial connectivity
Provides management of the UPS via RS-232(USB optional)
1KVA Front panel:
1KVA Back panel:
Package info:
Model Name |
NT-1K |
NT-1.4K |
NT-2K |
NT-3K |
NT-4K |
NT-5K |
NT-6K |
NT-8K |
NT-10K |
Capacity (VA / Watt) |
1KVA / 700W |
1.4KVA / 980W |
2KVA / 1400W |
3KVA / 2100W |
4KVA / 2800W |
5KVA / 3500W |
6KVA / 4200KW |
8KVA / 5.6KW |
10KVA/7KW |
Overview |
Power Factor |
0.7 |
|
Surge Protection Only (VA) |
No |
|
Outlook |
Tower or Rack Mount (2U) |
Tower or Rack (3U) |
Tower or Rack (3U) |
Tower |
|
Design Type |
Line Interactive |
|
Waveform |
True Sine wave |
|
AVR Function |
Boost, Buck |
|
AVR Active LED Indicator |
Boost, Buck |
Input |
Nominal Voltage |
115/230Vac |
230Vac |
|
Voltage Range |
92~138V/184~276V (±20%) 86~144V/173~288V (±25%)-Defaul t 80~150V/160~300V (±30%) |
184~276V (±20%) 1 73~288V (±25%)-Default 160~300V (±30%) |
|
Frequency Range |
(50/60Hz)±5% Auto sensing |
|
Socket Type |
Power Cord+C.B->115V Socket+Fuse Holder->230V |
Terminal block +breaker |
Output |
Nominal Voltage |
115/230Vac |
230Vac |
|
Voltage Range (AC Mode) |
106~121V/212~243V (+10~ -15%) 100~126V/200~253V(+10~ -15%) 93~132V/196~264V (+10~ -15%) |
212~243V (+10~ -15%) 200~253V (+10~ -15%) 196~264V(+10~ -15%) |
|
Voltage Range (Batt. Mode) |
(110/115/120/220/230/240V)±3%@ Resistive Load |
(220/230/240V)±3%@ Resistive Load |
|
Frequency Range |
(50/60Hz)±0.5% |
|
Socket Q'ty (Backup+Surge) |
(NEMA/IEC)*6pcs, |
(NEMA/IEC)*8pcs |
IEC C14*4pcs + terminal block |
IEC C14*8pcs + terminal block |
Overload |
Overload Protection (AC Mode) |
Alarm (Fuse or C.B Protection) |
|
Overload Protection (Batt Mode) |
110~140%->20Sec, >140%->5Sec. |
Battery |
Back-up (Half Load) |
STD->10~25min/STD+Batt->0.5~2hrs Long Backup->2~8hr |
>10~25min |
|
Volatge |
24VDC |
48VDC |
|
Quantity |
12V/7AH * 2 |
12V/9AH * 2 |
12V9AH * 4 |
12V12AH * 4 |
12V12AH * 8 |
12V12AH * 12 |
|
Cold Start (DC Start) |
Yes |
|
Replacement |
Hot Swap |
|
Charger Current (STD) Internal |
1.1K~1.4K->1.5A max. |
2200~3000->1.5 max. |
3A max. |
4A max. |
|
Charger Current (Large) External |
1000L->10A max. |
2200L~3000L->15A max. |
25A max. |
N/C. |
|
Charger Over Protection |
Yes |
|
Charging When UPS off |
Yes |
|
Green Power Mode Function |
yes |
|
Microprocessor Control |
Yes |
Data Line |
Network Protection |
RJ45 (1 in/1 out) |
N/A |
Communication |
Intelligent Interface |
RS232+Contact Closure |
|
Software (UPSILON 2000) |
Optional |
|
SNMP Card |
Optional |
Display |
LED Status |
Line/Batt Mode,Overload,Fault,Batt Replacement |
|
LCD (OPTIONAL) |
O/P voltage ,Input voltage ,Load size. Model |
Physicial |
Dimension(DxWxH) |
455x430x90mm |
455x430x135mm |
455x430x135mm |
540*340*710mm |
Weight |
Net weight |
16.2KG |
18KG |
26.8KG->2.2K |
34.5KG->3K |
28.5KG->4K ( UPS) 39KG->8BP1212 |
28.5KG->5K ( UPS) 39KG->8BP1212 |
28.5KG->6K ( UPS) 39KG->8BP1212 |
90KG->8K |
102KG->10K |
11KG |
13.5KG |
20KG->2.2KL |
22.1KG->3KL |
30.5KG->4KL |
36.8KG->5KL |
36.8KG->6KL |
65KG->8KL |
65KG->10KL |