The primary purpose of any fuse cutouts is to provide protection to the lines of your system and the various apparatus on those lines such as transformers and capacitor banks. Fuse cutouts provide reliable protection from low-level overloads that just melt the fuse link, intermediate faults, and very high faults, through maximum interrupting capacity.
No. | Type |
Rated voltage (kV) |
Rated current (A) |
Breaking current (A) |
Impulse voltage (BIL) |
Power-frequency with stand voltage (KV) |
Leakage distance (MM) |
Weight(KG) | Dimensions (CM) |
1 | (H)RW11 | 10(F) | 100(200) | 6300 | 110 | 42 | 260 | 7.5 | 48x32x27 |
2 | (H)RW10 | 10(F) | 100(200) | 8000 | 110 | 42 | 260 | 9.5 |
No. | Type |
Rated voltage (kV) |
Rated current (A) |
Breaking current (A) |
Impulse voltage (BIL) |
Power-frequency with stand voltage (KV) |
Leakage distance (MM) |
Weight(KG) | Dimensions (CM) |
1 | GWNCX1 | 12 | 100 | 6300 | 125 | 42 | 260 | 7.5 | 58x32x11.5 |
2 | GWNCX2 | 12 | 200 | 12500 | 125 | 42 | 260 | 7.5 |
No. | Type |
Rated voltage (kV) |
Rated current (A) |
Breaking current (A) |
Impulse voltage (BIL) |
Power-frequency withstand voltage (KV) |
Leakage distance (MM) |
Weight(KG) | Dimensions (CM) |
1 | (H)FCR | 11/15(F) | 100 | 6300 | 110 | 42 | 260 | 7.5 | 58x32x11.5 |
2 | (H)FCR | 11/15(F) | 200 | 12500 | 110 | 42 | 260 | 7.5 |
No. | Type |
Rated voltage (kV) |
Rated current (A) |
Breaking current (A) |
Impulse voltage (BIL) |
Power-frequency withstand voltage (KV) |
Leakage distance (MM) |
Weight (KG) |
Dimensions (CM) |
1 | (H)FCR | 24/33(F) | 100 | 6300 | 150 | 70 | 750 | 12 | 58x38.5x14.5 |
2 | (H)FCR | 24/33(F) | 200 | 12500 | 150 | 70 | 750 | 12 |
No. | Type |
Rated voltage (kV) |
Rated current (A) |
Breaking current (A) |
Impulse voltage (BIL) |
Power-frequency withstand voltage (KV) |
Leakage distance (MM) |
Weight (KG) |
Dimensions (CM) |
1 | (H)FCR | 33/36(F) | 100 | 10000 | 170 | 95 | 1000 | 14 | 70.5x39.5x14.5 |
2 | (H)FCR | 33/36(F) | 200 | 12500 | 170 | 95 | 1000 | 14 |