Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
2K~20K (1-in/1-out) |
||||||
Model |
2K |
3K |
6K |
10K |
15K |
20K |
Capacity (VA/W) |
2K/1.6K |
3K/2.4K |
6K/4.8K |
10K/8K |
15K/12K |
20K/16K |
Input voltage |
220V±25%, 1-phase/3-wire |
|||||
Noise |
≤52dB (distance: 1m) |
≤55dB(distance: 1m) |
||||
Sizes (W×D×H,mm) |
530×240×592 |
624×343×760 |
||||
Weight (Kg) (w/o battery ) |
35 |
35 |
53 |
91 |
110 |
122 |
6K3~60K3(3-in/1-out) |
||||||||||||||
Model |
6K 3-1 |
10K 3-1 |
15K 3-1 |
20K 3-1 |
30K 3-1 |
40K 3-1 |
50K 3-1 |
60K 3-1 |
||||||
Capacity (VA/W) |
6K/4.8K |
10K/8K |
15K/12K |
20K/16K |
30K/24K |
40K/32K |
50K/40K |
60K/48K |
||||||
Input voltage |
380V±25%, 3-phase/5-wire |
|||||||||||||
Noise |
≤55dB(distance: 1m) |
≤60dB(distance: 1m) |
||||||||||||
Sizes (W×D×H,mm) |
530×240×592 |
624×343×1020 |
624×480×1100 |
|||||||||||
Weight (Kg) (w/o battery ) |
53 |
139 |
158 |
178 |
263 |
335 |
400 |
480 |
Input |
Frequency |
50Hz/60Hz±10% |
Power factor |
≥92% |
|
Output |
Voltage |
220V±0.5% |
Voltage regulation |
±1% (static); ±2% (dynamic) (20ms from 0-100% load change) |
|
Frequency regulation |
50Hz/60Hz±0.05%(on battery mode) |
|
Frequency tracking rate |
<1Hz/s |
|
Dynamic response |
±0.4%(100% load change) |
|
THD |
<3% @ linear load (full load); <5% @ non-linear load (full load) |
|
Waveform |
True sine wave |
|
Efficiency |
AC input to AC output |
≥91% |
Transfer time |
Mains fails or restores |
0s |
Battery |
Voltage |
192V for 2K to 20K ; 336V for 30K to 60K |
Charge time |
8 hours to 90% |
|
Alarm |
Battery discharge |
Beeps every four (4) seconds when AC mains fails |
Beep every one (1) second when battery voltage low |
||
Continuously beeps when stopping battery discharge |
||
Fault |
Continuously beeps |
|
Protection & Display |
Battery |
Automatically shutdown when battery low, no fuse switch protection. |
Overload |
Automatically jumps to BYPSS when 110~150% overload for 30 seconds and automatically resumes when overload removed. |
|
Over temperature |
Automatically jump to BYPSS when UPS internal temperature >85ºC, |
|
Short circuit |
Current limit, automatic shutdown, fuse and no fuse switch protection |
|
UPS abnormal |
Automatically jumps to BYPASS |
|
Noise filter |
10~10KHz at 40 db;100KHz~100MHz at 70db |
|
LCD display |
Display input voltage/frequency, battery voltage and output power (%) |
|
Environment |
Temperature |
-10~40ºC |
Relative humidity |
10%~90%(no condensation) |
|
Altitude |
150 |