• 380V/400V/415V Three Phase Online Module UPS
  • 380V/400V/415V Three Phase Online Module UPS
  • 380V/400V/415V Three Phase Online Module UPS
  • 380V/400V/415V Three Phase Online Module UPS

380V/400V/415V Three Phase Online Module UPS

Phase: Three Phase
Type: On-line
Protection: Overvoltage
Application: Industry
Classification: Lighting/Power
Standby Time: Long-acting Machine
Customization:
Diamond Member Since 2008

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
Tiger series
Standby UPS
Sine Wave Output UPS
Output Capacity
Medium Type
Equipment Mode
Centralized Model
Brand
Jetpower
Design
Online
Wave Form
True Sine Wave
Frequency
High
Output Voltage
380V/400V/415V
DC Voltage
480V
Warranty
2 Years
Transport Package
Plywood Case
Specification
CE, RoHS
Trademark
JETPOWER
Origin
China
HS Code
85044020
Production Capacity
500set/Week

Product Description

Tiger Series Module UPS (6-500kVA)
High frequency /online /3 Phase input and output /380V/400V/415V
 
Description
Tiger series three phase UPS offers advanced technology that increase performance and reliablility:three high speed DSPs with completed digital control fully ensure high quality of power supply, high input power factor and low input current distortion. It also offers humanization design: full front access of serviceability, user friendly interface.
 
Application
ISP(Internet service provider), IDC(Internet Data center)
Computer Room, Service Center
Precision instruments
Intelligent equipments
 
Features
Wide input voltage and frequency range, compatible with different utility
High input PF >0.99
Input Current THDi<3%
Full DSP Control
Online double conversion technology, output excellent sinusoidal wave
Intelligent battery management, greatly extend the battery life
Full protection, including back feed protection, battery leakage protection and so on
Parallel up to 6 power units
Modular design of subsystem, convenient for field maintenance
Friendly Operation Interface, touch LCD Screen

Specifications for Tiger Series 6K-40K UPS (380V/400V/415V)
Model Name 6KS 10KS 15KS 20KS 30KS 40KS
6KL 10KL 15KL 20KL 30KL 40KL
Input
Grid System 3 Phases + Neutral + Ground
Rated Voltage 380/400/415VAC (Line-Line)
Rated Frequency 50/60Hz
Voltage Range 304~478Vac (Line-Line),full load; 228V~304Vac (Line-Line),load decreases linearly according to the min phase voltage 
Frequency Range 40Hz~70Hz
Power Factor >0.99
Waveform True Sine Wave
Bypass Input
Rated Voltage 380/400/415VAC (Line-Line)
Rated Frequency 50/60Hz
Voltage Range Selectable,  default -20%~+15%; Upper limit: +10%, +15%, +20%, +25%; Lower limit: -10%,  -15%, -20%, -30%,  -40%
Frequency Range Selectable, ±1Hz, ±3Hz, ±5Hz
Overload 125% Long term operation; 125%~130% for 10min; 130%~150% for 1min;
Output
Rated Inverter Voltage 380/400/415VAC (Line-Line)
Rated Frequency 50/60Hz
Power Factor 1 0.9
Voltage Precision ±1.5%(0-100% linear load)
Transient Response  <5% for step load  (20% - 80% -20%)
Transient recovery < 30ms for step load (20% - 100% -20%)
Output Voltage THDu <1% (linear load);
<5.5% (non-linear load) according to IEC/EN62040-3
<1% linear load;
<6 (non-linear load) according to IEC/EN62040-3
Inverter Overload <110%, 60min; 110%~125%,10min; 125%~150%,1min;
Frequency Regulation 50/60Hz±0.1%
Synchronized Range Settable, ±0.5Hz ~ ±5Hz, default ±3Hz
Synchronized Slew Rate Settable, 0.5Hz/S ~ 3Hz/s, default 0.5Hz/s
Battery And Charger
Rate Voltage ±240VDC
Charger Voltage Precision 1%
Charger Power max=20%  System Power
Efficiency
Normal Operation 95%max >95% >96%
Battery Operation 94.5%max >95% >96%
System
Display  LCD+LED
Interface Standard: RS232, RS485; Option: SNMP, Dry Contact, Parallel kit, Battery cold start 
Environmental
Operation Temperature 0-40ºC
Storage Temperature -40 ~ 70 ºC
Relative Humidity 0-95% (non-comdensing)
Noise (1 meter) 58dB @ 100% load, 52dB @ 45% load 65dB @ 100% load, 62dB @ 45% load
Physical
Dimension  (D*W*Hmm) 250*840*715 250*840*715 350*738*1335 350*738*1335 500*840*1400
250*660*530 250*660*530 250*680*770 250*680*770 250*836*770
Net Weight (KG) 51.5(w/o battery) 89(w/o battery) 89(w/o battery) 140
31 50 52 61

Specifications for Tiger Series 60K-500K UPS (380V/400V/415V)
Model Name 60K 80K 90K 100K 120K 150K 200K 250K 300K 400K 500K
Input
Grid System 3 Phases + Neutral + Ground
Rated Voltage 380/400/415VAC (Line-Line)
Rated Frequency 50/60Hz
Voltage Range 304~478Vac (Line-Line),full load; 228V~304Vac (Line-Line),load decrease linearly according to the min phase voltage 
Frequency Range 40Hz~70Hz
Power Factor >0.99
 Current THDi <3% (full Linear Load)
Bypass Input
Rated Voltage 380/400/415VAC (Line-Line)
Rated Frequency 50/60Hz
Voltage Range Selectable,  default -20%~+15%; Up limited: +10%, +15%, +20%, +25%; Down limited: -10%,  -15%, -20%, -30%,  -40%
Frequency Range Selectable, ±1Hz, ±3Hz, ±5Hz
Overload 125%, long time operation
125%< load <130%, last for more than 10 minutes
130%<load<150%,last for more than 1 minutes
>150%, last for more than 300ms
110% Long term operation
110%~125% last for more than 5min
125%~150% last for more than 1min
>150% last for more than 1s
Output
Rated Inverter Voltage 380/400/415VAC (Line-Line)
Rated Frequency 50/60Hz
Power Factor 0.9
Voltage Precision ±2%
Transient Response  <5% for step load  (20% - 80% -20%)
Transient recovery < 30ms for step load (0% - 100% -0%)
Output Voltage THDu <1.5% from 0% to 100% linear load; <6% full non-linear load according to IEC/EN62040-3
Inverter Overload <110%, 60min; 110%~125%,10min; 125%~150%,1min; >150%,200ms
Frequency Regulation 50/60Hz±0.1%
Synchronized Range Settable, ±0.5Hz ~ ±5Hz, default ±3Hz
Synchronized Slew Rate Settable, 0.5Hz/S ~ 3Hz/S, default 0.5Hz/S
Battery And Charger
Rate Voltage ±240VDC
Charger Voltage Precision 1%
Charger Power max=20% Output power
Efficiency
Normal Operation >95% >96% >95% >96% >95% >96%
Battery Operation >95% >96% >95% >96% >95% >96%
System
Display  LED + LCD + touch screen
Interface RS232, RS485, USB,Programmable dry contact RS232, RS485, USB,Programmable dry contact,battery cold start
Option battery cold start,SNMP,AS400,parallel kit,Lightning protection components,Dust Filter,LBS SNMP,AS400,parallel kit,Lightning protection components,Dust Filter,LBS
Environmental
Operation Temperature 0-40ºC
Storage Temperature -40 ~ 70 ºC
Relative Humidity 0-95% (non-comdensing)
Noise (1 meter) 65dB @ 100% load, 62dB @ 45% load
Altitude <1000m, Load derated 1% per 100m From 1000 ~ 2000m
Physical
Dimension  (D*W*Hmm) 600*980*950 600*980*1150 600*980*1400 600*980 *1150 600*980*1400 650*960*1600 650*960*2000 1300*1100*2000
Net Weight (KG) 170 210 231 210 266 305 350 445 490 810 900
NOTE: Product specifications are subject to change without further notice.
380V/400V/415V Three Phase Online Module UPS380V/400V/415V Three Phase Online Module UPS




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2008

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2007-03-05
Registered Capital