• Drop-out Fused Cut out and Load Switching Fuse Cutout
  • Drop-out Fused Cut out and Load Switching Fuse Cutout
  • Drop-out Fused Cut out and Load Switching Fuse Cutout
  • Drop-out Fused Cut out and Load Switching Fuse Cutout
  • Drop-out Fused Cut out and Load Switching Fuse Cutout
  • Drop-out Fused Cut out and Load Switching Fuse Cutout

Drop-out Fused Cut out and Load Switching Fuse Cutout

Breaking Capacity: High
Type: Current Fuse
Usage: High Voltage
Shape: Spiral
Fusing Speed: F
Fusing Device: Pop-up Solid
Customization:
Diamond Member Since 2008

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
Cutout
Application
Outdoor
Transport Package
1PCS/Carton
Specification
CE, ISO9001
Trademark
JETPOWER
Origin
China
HS Code
85462090
Production Capacity
100PCS/Day

Product Description

Drop-out Fused Cut out and Load Switching Fuse CutoutDrop-out Fused Cut out and Load Switching Fuse Cutout
DROP OUT FUSE CUTOUT
 SERIES

Drop-out fused cut out and load Switching fuse cutout are of outdoor used high voltage protective device.To be connected with incoming feeder of distribution line, it mainly protect transformer or lines from short circuit and overload,and on/off loading current.

Drop-out fused cutout is composed of insulator supports and fuse tube, static contacts is fixed on two sides of insulator support and moving contact is installed on two ends of fuse tube . Fuse tube is composed of inside arc-estinguishing tube, outer phenolic compound paper tube or expoxy glass tube.

Load switching fuse cutout provides enforced elastic auxiliary contacts and arc-extinguishing enclosure for switching on/off loading current. At normal working via fuselink tightened the fuse tube is fixed to form up of close position.
In case system occur faults, fault current result in fuse melt immediately and take place electric arc, which let arc-extinguishing tube being heated and ex-plode a lot of gas. This will produce high pressure and blow off the arc along with tube.
After fuselink melt moving contact has no tightened strength again, mechanism is locked and fuse tube dropout. Cutout now is in open position.When it needs to switch off during cut out loading. operator shall via insulating operating bar pull the moving contact, at its beginning main contact and auxiliary static contact is contacted still. Whiling pulling the auxiliary contact is separated between auxiliary contacts there occur electric arc and the arc will be lengthened in arc-extinguishing enclosure gap and meanwhile arc- extinguishing explode gas to blow off  the arc during current passing zero

Drop-out Fused Cut out and Load Switching Fuse Cutout
No. Type
 
Rated
voltage
(kV)
 
Rated
current (A)
 
Breaking current (A)
 
Impulse voltage
(BIL)
 
Power-frequency with stand voltage
(KV)
Leakage distance
(MM)
Weight(KG) Dimensions (CM)
1 (H)RW11 10(F) 100(200) 6300 110 42 260 7.5 48x32x27
2 (H)RW10 10(F) 100(200) 8000 110 42 260 9.5

Drop-out Fused Cut out and Load Switching Fuse CutoutDrop-out Fused Cut out and Load Switching Fuse Cutout
No. Type
 
Rated
voltage
(kV)
 
Rated
current (A)
 
Breaking current (A)
 
Impulse voltage
(BIL)
 
Power-frequency with stand voltage
(KV)
Leakage distance
(MM)
Weight(KG) Dimensions (CM)
1 GWNCX1 12 100 6300 125 42 260 7.5 58x32x11.5
2 GWNCX2 12 200 12500 125 42 260 7.5
Drop-out Fused Cut out and Load Switching Fuse CutoutDrop-out Fused Cut out and Load Switching Fuse CutoutDrop-out Fused Cut out and Load Switching Fuse Cutout

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2008

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2007-03-05
Registered Capital
3.13 Million USD