Model Name |
PSRT1100 |
PSRT1500 |
PSRT2000 |
PSRT2000L |
PSRT3000L |
|
Overview |
Capacity (VA / Watt) |
1100VA / 715W |
1500VA / 975W |
2000VA / 1300W |
2000VA/1300W |
3000VA/1950W |
|
Surge Protection Only (VA) |
1100VA |
1500VA |
2000VA |
2000VA |
3000VA |
|
Power Factor |
0.65 |
0.65 |
0.65 |
0.65 |
0.65 |
|
Outlook |
Tower/Rack |
Tower/Rack |
Tower/Rack |
Tower/Rack |
Tower/Rack |
|
Design Type |
Line Interactive |
Line Interactive |
Line Interactive |
Line Interactive |
Line Interactive |
|
Waveform |
Sine wave |
Sine wave |
Sine wave |
Sine wave |
Sine wave |
|
AVR Function |
Boost, Buck |
Boost, Buck |
Boost, Buck |
Boost, Buck |
Boost, Buck |
|
AVR Active LED Indicator |
Boost, Buck |
Boost, Buck |
Boost, Buck |
Boost, Buck |
Boost, Buck |
|
Input |
I/P Nominal Voltage |
115 or 230Vac |
115 or 230Vac |
115 or 230Vac |
115 or 230Vac |
115 or 230Vac |
|
I/P Voltage Range |
86~144V/165~275V |
86~144V/165~275V |
86~144V/165~275V |
86~144V/165~275V |
86~144V/165~275V |
|
I/P Voltage Range (Duble AVR) |
No |
No |
No |
No |
No |
|
I/P Frequency Range |
115V/50Hz--> 230V± 6Hz " > 60Hz--> 115V/50Hz--> 230V± 6Hz |
115V/50Hz--> 230V± 6Hz " > 60Hz--> 115V/50Hz--> 230V± 6Hz |
115V/50Hz--> 230V± 6Hz " > 60Hz--> 115V/50Hz--> 230V± 6Hz |
115V/50Hz--> 230V± 6Hz " > 60Hz--> 115V/50Hz--> 230V± 6Hz |
115V/50Hz--> 230V± 6Hz " > 60Hz--> 115V/50Hz--> 230V± 6Hz |
|
I/P Power Line Surge (115V/230V) |
1482/476 Joules |
1482/476 Joules |
1482/476 Joules |
1482/476 Joules |
1482/476 Joules |
|
I/P Socket Type |
115V Inlet Socket+C. B-> 230V " > Power Cord+C. B-> 115V Inlet Socket+C. B-> 230V |
115V Inlet Socket+C. B-> 230V " > Power Cord+C. B-> 115V Inlet Socket+C. B-> 230V |
115V Inlet Socket+C. B-> 230V " > Power Cord+C. B-> 115V Inlet Socket+C. B-> 230V |
115V Inlet Socket+C. B-> 230V " > Power Cord+C. B-> 115V Inlet Socket+C. B-> 230V |
115V Inlet Socket+C. B-> 230V " > Power Cord+C. B-> 115V Inlet Socket+C. B-> 230V |
|
Output |
O/P Nominal Voltage |
115/230Vac |
115/230Vac |
115/230Vac |
115/230Vac |
115/230Vac |
|
O/P Voltage Range (AC Mode) |
100~127V/200~253V (+10~-13%) |
100~127V/200~253V (+10~-13%) |
100~127V/200~253V (+10~-13%) |
100~127V/200~253V (+10~-13%) |
100~127V/200~253V (+10~-13%) |
|
O/P Voltage Range (Double AVR) |
No |
No |
No |
No |
No |
|
O/P Voltage Range (Batt. Mode) |
111~118V/223~236.9V (± 3%) |
111~118V/223~236.9V (± 3%) |
111~118V/223~236.9V (± 3%) |
111~118V/223~236.9V (± 3%) |
111~118V/223~236.9V (± 3%) |
|
O/P Frequency Stability |
50/60Hz +/- 0.5% |
50/60Hz +/- 0.5% |
50/60Hz +/- 0.5% |
50/60Hz +/- 0.5% |
50/60Hz +/- 0.5% |
|
O/P Manual Configature Set |
No |
No |
No |
No |
No |
|
O/P Socket Q' ty (Backup+Surge) |
(NEMA/IEC)*6 |
(NEMA/IEC)*6 |
(NEMA/IEC)*6 |
(NEMA/IEC)*4 |
(NEMA/IEC)*4 |
|
Transfer Time |
< 4ms (typical) |
< 4ms (typical) |
< 4ms (typical) |
< 4ms (typical) |
< 4ms (typical) |
|
Overload |
Overload Protection (AC Mode) |
110 Buzzer Alarm, " > > 110 Buzzer Alarm, |
110 Buzzer Alarm, " > > 110 Buzzer Alarm, |
110 Buzzer Alarm, " > > 110 Buzzer Alarm, |
110 Buzzer Alarm, " > > 110 Buzzer Alarm, |
110 Buzzer Alarm, " > > 110 Buzzer Alarm, |
|
Overload Protection (Batt Mode) |
110~140%-> 20Sec S/D, > 140%-> immed UPS Off. |
110~140%-> 20Sec S/D, > 140%-> immed UPS Off. |
110~140%-> 20Sec S/D, > 140%-> immed UPS Off. |
110~140%-> 20Sec S/D, > 140%-> immed UPS Off. |
110~140%-> 20Sec S/D, > 140%-> immed UPS Off. |
|
Battery |
Backup Time-Full Load |
3 Minutes |
3 Minutes |
3 Minutes |
Depend on the external battery |
Depend on the external battery |
|
Back-up Time-Half Load |
3~20 minutes Depends on load |
3~20 minutes Depends on load |
3~20 minutes Depends on load |
Depend on the external battery |
Depend on the external battery |
|
Battery Volatge & Quantity |
24VDC (12V/7AH*2) |
24VDC (12V/8AH*2) |
24VDC (12V/7AH*4) |
48Vdc |
48Vdc |
|
Battery Cold Start (DC Start) |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Battery Replacement |
Easy Replacement |
Easy Replacement |
Easy Replacement |
N/A |
N/A |
|
External Battery |
No |
No |
No |
Yes |
Yes |
|
Charger Current (STD) Internal |
1A Max. |
1A Max. |
1.5A Max. |
N/A |
N/A |
|
Charger Current (Large) External |
No |
No |
No |
7A~10A |
7A~10A |
|
Charger Over Protection |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Charging When UPS off |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Microprocessor Control |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Data Line |
TEL/FAX/Modem/DSL/Network Protection |
RJ11 (1 in/1 out) RJ45(1 in/1 out) |
RJ11 (1 in/1 out) RJ45(1 in/1 out) |
RJ11 (1 in/1 out) RJ45(1 in/1 out) |
RJ45(1 in/1 out) |
RJ45(1 in/1 out) |
|
Data Line Surge Energy Joules |
108 Joules |
108 Joules |
108 Joules |
108 Joules |
108 Joules |
|
Communication |
Intelligent Interface |
RS232 |
RS232 |
RS232 |
RS232 |
RS232 |
|
RS232 Cable Type |
RS232 Cable |
RS232 Cable |
RS232 Cable |
RS232 Cable |
RS232 Cable |
|
Monitoring Software |
UPSilon2000 |
UPSilon2000 |
UPSilon2000 |
UPSilon2000 |
UPSilon2000 |
|
USB Cable (RS232-> USB) |
No |
No |
No |
NO |
NO |
|
SNMP Card |
NO |
NO |
NO |
NO |
NO |
|
Conformance |
Safety & EMC Approved |
CE |
CE |
CE |
CE |
CE |
|
Indicators LED Display |
4 LEDs on Front Panel |
4 LEDs on Front Panel |
4 LEDs on Front Panel |
4 LEDs on Front Panel |
4 LEDs on Front Panel |
|
Rear Panel LED (115V only) |
Red LED for Site Wire fault |
Red LED for Site Wire fault |
Red LED for Site Wire fault |
Red LED for Site Wire fault |
Red LED for Site Wire fault |
|
LED Status |
Line, Batt Mode/charger, Overload/Fault |
Line, Batt Mode/charger, Overload/Fault |
Line, Batt Mode/charger, Overload/Fault |
Line, Batt Mode/charger, Overload/Fault |
Line, Batt Mode/charger, Overload/Fault |
|
Environment |
Temperature |
0-40 degree C |
|
Humidity |
3000 Meters max Elevation 10-95% |
|
Audible Noise |
Less than 45dBA (at 1M) |
Less than 50dBA (at 1M) |
|
Physical |
Dimension(DxWxH) |
415*430*89 |
415*430*89 |
415*430*89 |
415*430*89 |
415*430*89 |
|
Weight (Kg/lb) |
20.4kg |
22kg |
28kg |
25 |
31 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|